Preparation Installing Electrical Installation

Bookmark and Share
Things - things to consider before installing the electrical installation is as follows:
 
* Plan the home.To determine the location of the Fuse Box / Box MCB, point lights, switches and SC (Stop Contacts / socket) and of course the lines are to be installed electrical installation. This Plan will be helpful for a number of common mistakes to avoid cable channel used due to branching channel lights, switch and SC.
 
* Equipment installation and equipment.Almost every household has the equipment for electrical installation such as combination pliers, screwdrivers, razor / blades / hacksaw, hammer betel and so we do not need to buy new .. might just have to buy test-pen. This tool is used to download the attached test electrical installations and much needed to repair electrical installations that have been installed. Because it is strongly recommended to have this tool. No need an expensive, important works fine. One more thing that is lighter (preferably a gas lighter cigarette lighter), but if there is no fire from the candles was so. Why yes ..?


 
* Determine the security being used.Safety is commonly used in electrical installations and building homes is a masing2 fuse and MCB have a different container or place the Fuse Box and Box MCB. Each has advantages and disadvantages. Here's a little description of my experience (not to read the books / literature lhoo ...).

    
Fuse Box.
Pros:
  
- It has two parts, namely the fuse connected in phase and disconnect switch (either phase or neutral) of the power source (PLN, diesel, etc.).
  
- If the fuse is damaged / broken due to short circuit can be improved, so no need to buy a new (standard fuse / common lhoo ..).
   
- Price fuse cheaper.Disadvantages:
   
- It's hard looking for a fuse box that is used to install a lot of group division. Generally there is only 1 group and 2 group installation.
    
- It looks less practical.

    
Box MCB.
Pros:
    
- Can be used for many plant groups.
    
- Looks practical and neater.Disadvantages:
    
- Usually only part of a given phase MCB safety of the power source (PLN, diesel, etc.).
    
- If you need to replace broken new MCB because it is difficult to fix.
    
- Price MCB is much more expensive than fuses.
 
* Determine the length of cable NYM 3 x 4 mm ² and 6 mm ² cable BC.
   
- As described above, NYM cable serves as the connecting cable from the power source (KWH meter PLN or Diesel) so decide wisely which should be the source of power and location of safety boxes. We recommend that you put the two are not far apart (± 50 cm) since the cable is quite expensive.
   
- As NYM cables, cable 6 mm ² BC also is quite expensive so it's good grounding rod placement is also not too far from a power source and a safety box is not too long so we bought it. For example usually Electric instatir install grounding rod / grounding perpendicular KWH meters below PLN that required cable BC ± 2 m.
 
* Determine the type, conductor cross-sectional area, and color wiring required in the installation.
   
• Type of cable.Commonly used in the installation of the cable is a type of Him (in cable consists only 1 wrapped solid copper conductor wire insulator) or a type of NYM (cable wrapped in insulation is composed of 2, 3 or 4 wire solid copper conductor). Want more wah longer cables NYY. Here we discuss the use of ITS alone (cheaper), for the use of other cables can customize.
   
• Conductor cross-sectional area.This involves the ability of the cable (in short the current carrying capability of the cable to the electric current passing through it). The size is 1.5 mm ², 2.5 mm ², 4 mm ², 6 mm ² ff. Actually the installation is done installing calculations on various factors including the large and determine the type of cable digunakan.Untuk we simply use the cable size 1.5 mm ² (for light line), 2.5 mm ² for the main channel and for the outlet (socket) actual use of the cable can be adjusted with the use of the socket. For those of you who are new will subscribe electricity from the state electricity company a good idea to use a cable 2.5 mm ² for each outlet although you will subscribe to 1300VA power down. What is not too big for wire tu SC? For questions on the realization is clumsy, especially for homes with installed power of 1300 VA down. The answer is still in my mind, sorry can not be published. Maybe next time time yaaa ... maybe .... he ... he ... heee ......
   
• Color cable.Cable color can be very, very helpful in the installation and repair of electrical installation, I also highly recommend it. PUIL mensyaratkat black cables for phase (shock), blue for neutral and green striped yellow (many are called yellow stripes) for ground wires. But the author does not require lhoo .. only suggest (it's your home, not the home state / government). According PUIL, it is for uniform installation in Indonesia so no salahmya followed. To make it easier again for those of you who are just learning we added one other colored wires (we take the example of red wire). This cable will offer for connecting from the switch to the lights only.
 
* Determine the length of cable required.If you have limited financial position, the following is very, very helpful because the biggest expense is the provision of electrical installation wiring installation. The math may be a little difficult for the cloud. Here the authors try to summarize it as simple as possible.
 
1. Determine the main line display electrical installations before branched (prior connected to a power outlet, switch or light fittings). Do not forget exceeded slightly (approximately 20cm) each have ramification (branch lines connect to both the switch and the SC).
  
- The main line of the old electrical installations using 2 cables are wired phase (shock) and neutral wires. But because many household appliances now have the induced currents flowing in the body equipment (eg, refrigerator, computer CPU) so many houses were later added the line cord ground (ground) on the main line that will be connected to the socket. The author highly-highly recommend adding ground wires on the main channel. But if you do not have the equipment causing the induced current, 2 wires enough.
 
2. Determine the length of the cable to the light fitting. Cables for light fittings are needed two cables. Do not forget exceeded slightly (about 20cm)
 
3. Determine the length of the cable to the switch. The number of cables required depends on the type of switch. Single switch takes 2 pieces of cable, switch doble takes 3 pieces of cable, and so on. Do not forget exceeded slightly (about 20cm)
 
4. Determine the length of the cable into the socket. If the cable channel 2 main pieces of the cord into the wall socket is also 2 pieces. But if the main cable channel 3 pieces of the cable outlet is also 3 pieces. Do not forget exceeded slightly (about 20cm)
  
- For placement of switches and sockets are contiguous (usually in the bedroom and living room) calculation is the number of cable wires switch plus an amount later reduced terminal 1 piece of cable. Do not bother yaa ...
 
* Calculate the length of the pipe installation is required.In short-term calculation is the main channel plus the length of the branch line to the outlet or switch. For placement adjacent SC switch and can be used a pipe and then the second N-bownya can be modified to connect. Do not forget to specify the number of L-bow/penyambung pipe elbow (90 degree bend).
 
* Counts the number of switches, sockets and light fittings.
 
* Counts the number of In-BOUW doos / home switch or SC (if placement in the wall) and the number of T-doos and Kruis doos which is the main channel connecting the branch channel (switches, sockets).